MTP to MTP Patch Cables; OM3 (50/125) 12 fibre

For 40GBASE-SR4 or 100GBASE-SR4

Home > MPO MTP Networking > M400 Series SR4 / LR4 > MTP to MTP Patch Cables > MTP to MTP OM3 Patch Cables

secure shopping

MTP to MTP Patch Cables

Polarity 40G SR4 and 100G SR4

MTP to MTP patch cables are mainly used to two ways; to directly connect between two QSFP+ (or QSFP28) transceivers or to connect MTP trunk cables to QSFP+ (QSFP28) transceivers. The MTP to MTP patch cables sold online here are for the first application.  Complete Connect also stock MTP patch cables for the second application but these are not offered online due to ensuring the right type of cable is supplied. MTP patch cables with polarity B and with female (no pin) connectors on each end will enable a direct connection for SR4 transmission between two QSFP type transceivers.

Using the low loss MT ELITE ferrule and Corning Clearcurve glass, Complete Connect offer MTP patch cables with guaranteed performance and compatibility. These MTP patch cables are part of our M400 Series and offer customers a complete network that supports both 40GBASE-SR4 network and 100GBASE-SR4.

Product Series M400 SR4
Polarity B – SR4 (40G/56G/100G)
Fibre Type OM3 (50/125)
Fibre Capacity 12
Glass Fibre Corning Clearcurve®
Connector End 1 MTP® ELITE 12 fibre female
Connector End 2 MTP® ELITE 12 fibre female
Insertion Loss across cable < 0.45 dB
Product Warranty 25 year fully covered
Made-to-Order Options
1. Fibre Type M404 Series – OM4 (50/125) for 40GBASE-SR4 or 100GBASE-SR4
2. Cable Type Single sheath 3.0mm
Dual sheath 4.5mm
3. MTP Connector Gender MTP female (no pins) to MTP female (no pins)
MTP male to MTP male (with pins)
MTP male (no pins) to MTP female (no pins)
4. Polarity 40G and 100G SR4 (B), A or C
5. Quick Release Tabs Optional
Compatibility with QSFP+ transceiver modules
  1. All QSFP+ 40GBase-SR4 transceiver modules have ports with male connections (with guide pins). The MTP cable needs a female connector (no pins)
  2. Transceivers from the leading switch manufacturers such as CISCO, Juniper, Extreme, HP, Dell, Arista and Brocade all use an MT ferrule.
  3. All Complete Connect 40G cables use the MT Elite ferrule within the MTP 12 fibre connector. This provides the best optical connection with all major QSFP+ transceivers. Some MPO connectors wont perform as well.
Cleaning MTP cables and transceiver ports
  1. Complete Connect recommend using an IBC Branded MTP cleaning tool for cleaning all MTP cables and QSFP+ transceiver ports.
  2. Complete Connect will supply this free of charge on orders of four or more 40G cables
Maximum transmission distances
  1. The IEEE standard states that 400G can be transmitted at the following distances: OM3 less than 100m; OM4 less than 150m.
Testing using Loopback adaptor cables
  1. 40G loopback cables can be used to test individual components or networks.

M403 Series – OM3 Patch Cables: total length – 1m, 2m, 3m, 5m or 10m

1. Fibre Type M403 Series – OM3 (50/125) for 40GBASE-SR4 or 100GBASE-SR4
2. Cable Type Single sheath 3.0mm
3. Connector Gender MTP female (no pins) to MTP female (no pins)
4. Total Length 1m, 2m, 3m, 5m and 10m
5. Polarity B – SR4 (40G/56G/100G)
Looking for QSFP+ to QSFP+ Direct Attach Copper (DAC) Cables
QSFP28 QSFP28 100G direct attach copper DAC Cable

Applications of MTP patch cables

Direct QSFP+ to QSFP+
Direct QSFP28 to QSFP28
Patch to 40G trunks
Patch SR4 100G trunks
40G or 100G SR4 cross connects

Key Features

MTP® ELITE® low loss connectors
Corning® ClearCurve® glass
Tight bend radius cable construction
Dual sheath option

Why choose our MTP Patch Cords?

Dual wavelength testing
Small diameter, light cable construction
Supplied from the UK
The Complete Connect Triple lock – Price Match / Compatibility / Warranty

MTP to MTP Patch Cable Technical Drawings
MTP to MTP Patch Cable: Standard Stocked Cable
qsfp+ 40G MTP fibre patch cable
MTP to MTP Patch Cable Polarity B SR4 40G/100G
Polarity B for SR4 40G Patch Cable
MTP Patch Cable: Single Sheath Cable Construction
12 fibre micro core loose tube cable
MTP Patch Cable: Dual Sheath Cable Construction
12 fibre micro core loose tube cable dual sheath
40GBASE Direct Connect

Directly connect two 40GBASE ports together using an MTP patch cable or trunk cable

Complete Connect 40G (QSFP+) Optical Transceiver

SR4 850nm – MPO/MTP Interface

M400 Series SR4 MTP to MTP Patch Cable

OM3 or OM4 for SR4
Singlemode for PLR4 (LR4 PSM)

Complete Connect 40G (QSFP+) Optical Transceiver

SR4 850nm – MPO/MTP Interface

40GBASE Direct Connect

Directly connect two 40GBASE ports together using an MTP patch cable or trunk cable

Complete Connect 40G (QSFP+) Optical Tranceiver

SR4 850nm – MPO/MTP Interface

M400 Series SR4 MTP to MTP Patch Cable

OM3 or OM4 for SR4
Singlemode for PLR4 (LR4 PSM)

Complete Connect MTP Adaptor Plates

For Key up / Key down adaptors / couplers

Optical and Physical Specifications
MTP Multimode ELITE OM3 Connector

Complete Connect only use the MTP connector with the ELITE low loss UPC ferrule. Universally compatible with all transceivers and other cabling systems.

Connector Housing Aqua
Ferrule MT ELITE
Typical Insertion Loss 0.10 dB (average)
Maximum Insertion Loss 0.35 dB (Max)
Physical Specification
Single Sheath Dual Sheath
Weight kg/Km 8 23
Outer Diameter 3.0mm 4.5mm
Sheath Wall Thickness (nominal ave. mm) 0.55mm Inner 0.55mm, outer 0.45mm
Sheath Wall Thickness (minimum mm) 0.48mm Inner 0.48mm, outer 0.35mm
Maximum pull force 300 N 1000 N
Transport and storage – 25 °C to + 70 °C – 25 °C to + 70 °C
Installation – 5 °C to + 50 °C – 5 °C to + 50 °C
Installed – 10 °C to + 70 °C – 10 °C to + 70 °C
Minimum Bend Radius (installed) 10 x outside diameter 10 x outside diameter
Minimum Bend Radius (installation) 15 x outside diameter 15 x outside diameter
Maximum Crush Resistant (long term) 150 N/dm 300 N/dm
Jacket Colour OM3 – Aqua OM3 – Aqua
Construction
Single Sheath Dual Sheath
Design Twelve 250um fibres with aramid yarn strain relief
Single sheath
Twelve 250um fibres with aramid yarn strain relief
Dual sheath separated by aramid yarn strain relief
Construction Dry Loose Tube (no gel) Dry Loose Tube (no gel)
Sheath Properties LSZH – Halogen free, flame retardant LSZH – Halogen free, flame retardant
Application Indoor, cable trays and ducting Indoor, cable trays and ducting
Fire Performance
Flame Retardancy acc. IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke Density acc. IEC 61034
Halogen-free acc. IEC 60754-1
Acidity of Combustion Gases acc. IEC 60754-2
Cable Design
Multimode OM3
(50/125)
Optical Core 50μm +/- 2.5μm diameter
Optical Claddinng 125μm +/- 1μm diameter
Primary Acrylate Coating 242μm +/- 5μm diameter
Core Concentricity 1.5μm
Core Concentricity Error <5%
Optical Performance
Multimode OM3 (50/125)
Attenuation Coefficient
dB/Km (installed)
850nm ≤ 2.5 Max
1300nm ≤0.7 Max
Attenuation Coefficient
dB/Km (un-installed)
850nm ≤ 2.3 Max
1300nm ≤0.6 Max
Overfill Launch Minimum
Bandwidth Mhz x Km
850nm ≥ 1500
1300nm ≥ 500
Laser Effective Modal Minimum
Bandwidth Mhz x Km
850nm ≥ 2000
Commitment to Excellence

Complete Connect are committed to providing the highest quality performing products. This is achieved through

  • Sourcing the best components
  • Utilising the lastest fibre termination technology
  • Maintaining rigorous processes
Cable Standards

TIA/EIA-568-C.3 and ISO/IEC 11801

Connector Standard

MPO: IEC-61754-7, EIA/TIA-604-5
Compliant to Directive 2002/95/EC (RoHS) and REACH SvHC

LC: IEC-61754-20
SC: IEC-61754-14
IEC-60793

Creating An SR4 Network

Using existing 10G standard fibre cabling and 40G

Complete Connect M400 Series 40G MTP to LC Duplex splitter cables enable a 40G connection between incumbent LC patch panels. Polarity is critical to ensure performance and can be managed through correct connection of the LC tails on the splitter cable to the panel.

Create a new 40G fibre cabling network

M400 Series 40G cabling will create a stand alone 40G network. Installed cabling can exactly match the requirement avoiding overspend and expansion is modular so future requirements are easily met.

Installation requires no specialist fibre cabling skills and is quick and error free. The polarity of the network is easily managed and the network can be installed at a convenient time.

QSFP_mtp_patch_cords

Using existing 10G MTP cabling and 40G

Complete Connect M400 Series MTP – LC Breakout/Splitter cables and MTP patch cables enable a 40G connection using incumbent 12 fibre MTP trunk cables. Typically, this involves the removal of MTP-LC cassette modules at one end and replacing these with MTP coupler plates.

The MTP-LC cassette modules can then be re-used in other areas of the network. Complete Connect M310 Series cables are compatible with cables from other manufacturers such as Corning Pre-tium EDGE, Systimax 360 or Panduit Quicknet so changing to Complete Connect M Series is straightforward.

40G_10G_Cassette

CALL

+44 (0)20 8286 6529